Delta DVP02LC-SL Load cell module, 2 channels, 24 bit RS-485
Product Description
Delta DVP02LC-SL Load cell module, 2 channels, 24 bit RS-485
Specifications
Rated power supply voltage/power consumption  | 24 VDC (-15 to +20%)/3 W  | 
Voltage boundary  | 18 to 31.2 VDC  | 
Max. current consumption  | 125 mA  | 
Input signal range  | +-40 mVDC  | 
Sensibility  | +5 VDC +/-10%  | 
Internal resolution  | 24 bits  | 
Communication port  | RS-232, RS-485  | 
Applicable sensor type  | 4-wire or 6-wire load cell  | 
Temperature coefficient span  | <=+- 50 ppm/K v. E  | 
Temperature coefficient zero point  | <= +- 0.4 uV/K  | 
Linearity error  | <= 0.02%  | 
Response time  | 2, 10, 20, 40, 80 ms × number of channels  | 
4 measuring ranges  | 0 to 1, 0 to 2, 0 to 4, 0 to 6 mV/V  | 
Max. distance for connecting to load cell  | 100m  | 
Max. current output  | 5 VDC × 300 mA  | 
Permitted load cell resistance  | 40 to 4,010 ?  | 
Common mode rejection (CMRR @50/60 Hz)  | >= 100dB  | 
Dynamic value filter  | Setting range: K1 to K5  | 
Average value filter  | Setting range: K1 to K100  | 
Isolation method  | 500 VAC between digital circuits and ground 500 VAC between analog circuits and ground 500 VAC between analog circuits and digital circuits  | 
Serial connection to DVP-PLC MPU  | Connectable to the left side of the MPU, numbered from 100 to 107 according to the position of the module from the closest to the farthest to the MPU.  | 
Operation/storage  | Operation: 0 to 55°C (temperature),50 to 95% (humidity), pollution degree 2 Storage: -25 to 70°C (temperature), 5 to 95% (humidity)  | 
Vibration/shock immunity  | International standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea)  | 

		
		