Sidebar
			
		
		 
				
						
        	
						
				
						 
				
														
					
									
				 	
				
						
					
												
				
				
					
			
						
		
						
			
		
				
			
										
		    
				
																									 					
					
						
																						
							
							
								
									
									
						            
										
	
	
	
										
																		
																	
								
					            					            
						            
					            
					            
					            
																
																
							
						
					
				
				
								
				
			
						
		
    
              Schneider VW3A7105 Braking unit - 100 kW - 400/480 V - for variable speed drive
						Viewed  1081 times
					
										
				Product Description
Schneider VW3A7105 Braking unit - 100 kW - 400/480 V - for variable speed drive
| product or component type | 
			 
				Resistance braking unit 
			 | 
			|
|---|---|---|
| range compatibility | 
			 
				Altivar Process ATV900 
			 | 
			|
| maximum braking power | 
			 
				160 kW 
			 | 
			|
| product compatibility | 
			 
				Variable speed drive ATV930 without braking chopper 110 kW 
				380...480 V 
			Variable speed drive ATV930 without braking chopper 130 kW 380...480 V Variable speed drive ATV930 without braking chopper 160 kW 380...480 V  | 
			|
| thermal losses | 
			 
				400 W 
			 | 
			|
| activation threshold | 
			 
				780 V DC +/- 1 % 
			 | 
			|
| permanent braking power | 
			 
				100 kW (at constant power and at engage threshold) 
			 | 
			|
| protection type | 
			 
				Integrated thermal protection by thermal probe 
			 | 
			|
| minimum resistor value to associate | 
			 
				2.5 Ohm 
			 | 
			
| electrical connection | 
			 
				Cable, connection capacity: 2 x 120 mm², 2 x 250 kcmil <= 5 m 
				between drive and braking unit 
			Cable, connection capacity: 2 x 120 mm², 2 x 250 kcmil <= 10 m between braking unit and braking resistors  | 
			|
|---|---|---|
| maximum DC bus voltage | 
			 
				850 V 
			 | 
			|
| load factor | 
			 
				0.05 for 320 kW at constant power and at engage threshold 
			0.15 for 250 kW at constant power and at engage threshold 0.5 for 200 kW at constant power and at engage threshold 1 for 160 kW at constant power and at engage threshold  | 
			|
| cycle time | 
			 
				<= 240 s 
			 | 
			|
| volume of cooling air | 
			 
				166 m3/h 
			 | 
			|
| operating position | 
			 
				Vertical +/- 10 degree 
			 | 
			|
| mechanical robustness | 
			 
				Vibrations class 3M4 conforming to IEC 60721-3-3 
			 | 
			|
| product weight | 
			 
				17 kg 
			 | 
			|
| width | 
			 
				216 mm 
			 | 
			|
| height | 
			 
				658 mm 
			 | 
			|
| depth | 
			 
				303 mm 
			 | 
			
| ambient air temperature for operation | 
			 
				-10...50 °C 
			 | 
			|
|---|---|---|
| ambient air temperature for storage | 
			 
				-40...70 °C 
			 | 
			|
| IP degree of protection | 
			 
				IP21 on top 
			IP20  | 
			|
| environmental characteristic | 
			 
				Chemical pollution resistance class 3C3 conforming to IEC 
				60721-3-3 
			Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3  | 
			|
| relative humidity | 
			 
				5...95 % without condensation 
			 | 
			|
| operating altitude | 
			 
				1000...4000 m with current derating 1 % per 100 m 
			<= 1000 m without derating  | 
		