Sidebar
			
		
		 
				
						
        	
						
				
						 
				
														
					
									
				 	
				
						
					
												
				
				
					
			
						
		
						
			
		
				
			
										
		    
				
																									 					
					
						
																						
							
							
								
									
									
						            
										
	
	
	
										
																		
																	
								
					            					            
						            
					            
					            
					            
																
																
							
						
					
				
				
								
				
			
						
		
    
              Schneider TMH2GDB Graphic display unit - 240 x 160 pixels
						Viewed  1255 times
					
										
				Product Description
Schneider TMH2GDB Graphic display unit - 240 x 160 pixels
| range of product | 
			 
				Modicon M221 
			 | 
			|
|---|---|---|
| product or component type | 
			 
				Graphic display 
			 | 
			|
| range compatibility | 
			 
				Modicon M221 
			 | 
			|
| current consumption | 
			 
				40 mA at 5 V DC via RJ45 connector 
			 | 
			|
| power consumption in W | 
			 
				<= 1 W 
			 | 
			|
| display type | 
			 
				Backlit colour STN LCD 
			 | 
			|
| display colour | 
			 
				Monochrome 
			 | 
			|
| display resolution | 
			 
				240 x 160 pixels 
			 | 
			|
| number of key | 
			 
				6 (for navigation) 
			4 (configurable)  | 
			
| standards | 
			 
				EN/IEC 61131-2 
			EN/IEC 61010-2-201  | 
			|
|---|---|---|
| product certifications | 
			 
				cULus 
			 | 
			|
| marking | 
			 
				CE 
			 | 
			|
| mounting location | 
			 
				Front cabinet Ø 22 mm hole 
			Bottom of cabinet Ø 22 mm hole, connection via mounting accessory  | 
			|
| connector type | 
			 
				RJ45 for communication and power supply 
			 | 
			|
| height | 
			 
				126 mm 
			 | 
			|
| width | 
			 
				80 mm 
			 | 
			|
| depth | 
			 
				63 mm 
			 | 
			|
| product weight | 
			 
				0.17 kg 
			 | 
			
| ambient air temperature for operation | 
			 
				-15...50 °C 
			 | 
			|
|---|---|---|
| operating altitude | 
			 
				0...2000 m 
			 | 
			|
| storage altitude | 
			 
				0...2000 m 
			 | 
			|
| environmental characteristic | 
			 
				Corrosive gas free 
			 | 
			|
| relative humidity | 
			 
				95 % non-condensing for operation 
			95 % non-condensing for transport 95 % non-condensing for storage  | 
			|
| ambient air temperature for storage | 
			 
				-40...70 °C 
			 | 
			|
| IP degree of protection | 
			 
				IP65 on front face 
			IP20 on back part  | 
			|
| pollution degree | 
			 
				2 conforming to EN/IEC 60664-1 
			 | 
			|
| vibration resistance | 
			 
				1.5 mm (f = 3...150 Hz 
			2 gn  | 
			|
| shock resistance | 
			 
				15 gn for 11 ms 
			 | 
			|
| electromagnetic compatibility | 
			 
				Radiated radio-frequency electromagnetic field immunity test 
				test level: 1 V/m - 2...3 GHz conforming to EN/IEC 61000-4-3 
			Disturbing field emission test level: 120...69 dBµV/m QP - power lines (DC) conforming to EN/IEC 55011 Electrical fast transient/burst immunity test test level: 1 kV conforming to EN/IEC 61000-4-4 Electrostatic discharge test level: 8 kV - air discharge conforming to EN/IEC 61000-4-2 Surge immunity test test level: 0.5 kV - common mode conforming to EN/IEC 61000-4-5 Disturbing field emission test level: 30...230 MHz - class A - 10 m conforming to EN/IEC 55011 Radiated radio-frequency electromagnetic field immunity test test level: 10 V/m - 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 Conducted RF disturbances test level: 10 Vrms - 0.15...80 MHz conforming to EN/IEC 61000-4-6 Disturbing field emission test level: 10...150 kHz - power lines (DC) conforming to EN/IEC 55011 Disturbing field emission test level: 150...1500 kHz - power lines (DC) conforming to EN/IEC 55011 Magnetic field at power frequency test level: 30 A/m - 50/60 Hz conforming to EN/IEC 61000-4-8 Electrostatic discharge test level: 4 kV - contact discharge conforming to EN/IEC 61000-4-2 Disturbing field emission test level: 1.5...30 kHz - power lines (DC) conforming to EN/IEC 55011 Surge immunity test test level: 0.5 kV - differential mode conforming to EN/IEC 61000-4-5 Radiated radio-frequency electromagnetic field immunity test test level: 3 V/m - 1.4...2 GHz conforming to EN/IEC 61000-4-3 Disturbing field emission test level: 230 MHz...1 GHZ - class A - 10 m conforming to EN/IEC 55011 Disturbing field emission test level: 79...63 dBμV/m QP - power lines (DC) conforming to EN/IEC 55011 Disturbing field emission test level: 40 dBμV/m QP - class A - 10 m conforming to EN/IEC 55011 Disturbing field emission test level: 47 dBμV/m QP - class A - 10 m conforming to EN/IEC 55011 Disturbing field emission test level: 63 dBμV/m QP - power lines (DC) conforming to EN/IEC 55011  | 
		