Sidebar
			
		
		 
				
						
        	
						
				
						 
				
														
					
									
				 	
				
						
					
												
				
				
					
			
						
		
						
			
		
				
			
										
		    
				
																									 					
					
						
																						
							
							
								
									
									
						            
										
	
	
	
										
																		
																	
								
					            					            
						            
					            
					            
					            
																
																
							
						
					
				
				
								
				
			
						
		
    
              Schneider TM3SAK6RG SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SPRING TERMINALS
						Viewed  1231 times
					
										
				Product Description
Schneider TM3SAK6RG SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SPRING TERMINALS
| range of product | 
			 
				Modicon TM3 Safety 
			 | 
			|
|---|---|---|
| product or component type | 
			 
				Safety module 
			 | 
			|
| device short name | 
			 
				TM3SAK 
			 | 
			|
| safety module application | 
			 
				For emergency stop, switch, sensing mat/edges or safety light 
				curtain monitoring 
			 | 
			|
| function of module | 
			 
				Emergency stop monitoring 1-channel wiring 
			Emergency stop monitoring 2-channel wiring Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Proximity sensor monitoring PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN Proximity sensor monitoring PNP/NPN Monitoring of a movable guard with 2 switches and automatic start  | 
			|
| safety level | 
			 
				Can reach PL e/category 4 EN/ISO 13849-1:2008 
			Can reach PL e/category 4 EN/ISO 13849-2:2012 Can reach SILCL 3 EN/IEC 62061:2005 Can reach SIL 3 EN/IEC 61508:2010  | 
			
| safety reliability data | 
			 
				DC = 95 % EN/ISO 13849-1 
			PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1  | 
			|
|---|---|---|
| synchronisation time between inputs | 
			 
				Unlimited 
			2 or 4 s depending of wiring configurable by software  | 
			|
| connections - terminals | 
			 
				Captive spring terminals, removable terminal block 1 x 0.2...1 x 
				2.5 mm² flexible without cable end 13-14, 23-24, 33-34 
			Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals  | 
			|
| output type | 
			 
				Relay instantaneous opening 3 NO potential free 
			 | 
			|
| number of safety circuits | 
			 
				3 NO (relay instantaneous opening) 
			 | 
			|
| maximum switching voltage | 
			 
				230 V utilisation category AC-15 at 50 Hz (relay instantaneous 
				opening) 
			24 V utilisation category DC-13 (relay instantaneous opening)  | 
			|
| [Us] rated supply voltage | 
			 
				24 V DC - 15...20 % 
			 | 
			|
| power consumption in W | 
			 
				0.2 W 5 V DC 
			3.6 W 24 V DC  | 
			|
| input protection type | 
			 
				Internal, electronic 
			 | 
			|
| [Uc] control circuit voltage | 
			 
				24 V DC 
			 | 
			|
| cable distance between devices | 
			 
				30 m 
			 | 
			|
| breaking capacity | 
			 
				360 VA holding AC-15 B300 relay output 
			3600 VA inrush AC-15 B300 relay output  | 
			|
| breaking capacity | 
			 
				4 A 24 V 50 ms DC-13 relay output 
			 | 
			|
| output thermal current | 
			 
				6 A per relay relay output 
			 | 
			|
| [Ith] conventional free air thermal current | 
			 
				18 A 
			 | 
			|
| associated fuse rating | 
			 
				4 A gG or gL relay output EN/IEC 60947-5-1 
			6 A fast blow relay output EN/IEC 60947-5-1  | 
			|
| minimum output current | 
			 
				10 mA relay output 
			 | 
			|
| output voltage | 
			 
				10 V relay output 
			 | 
			|
| response time on input open | 
			 
				<= 40 ms 
			 | 
			|
| [Ui] rated insulation voltage | 
			 
				300 V 2 IEC 60647-5-1 
			 | 
			|
| [Uimp] rated impulse withstand voltage | 
			 
				4 kV III IEC 60647-5-1 
			 | 
			|
| current consumption | 
			 
				100 mA 24 V DC external supply 
			 | 
			|
| local signalling | 
			 
				8 LEDs green/red user 
			 | 
			|
| electrical connection | 
			 
				Spring terminal 
			 | 
			|
| product compatibility | 
			 
				Safety light curtains EN/IEC 61496-1 (type 4) 
			Sensing mat/edges EN 1760-1  | 
			|
| standards | 
			 
				EN/ISO 13849-1:2008 
			EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012  | 
			|
| product certifications | 
			 
				ANSI Haz Loc Class 1 Division 2 (pending) 
			UL 61010-2-201 CSA 61010-2-201 (pending) TÜV CSA Haz Loc Class 1 Division 2 (pending) RCM EAC  | 
			|
| marking | 
			 
				TÜV 
			RCM EAC REACH EFUP 10 UL CSA CE  | 
			|
| electromagnetic compatibility | 
			 
				Electrostatic discharge immunity test 8 kV air discharge 
				conforming to EN/IEC 61000-4-2 
			Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011 Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011  | 
			|
| mounting support | 
			 
				Wall mount using attached fasteners 
			Rail top hat type TH35-7.5 IEC 60715 Rail top hat type TH35-15 IEC 60715  | 
			|
| height | 
			 
				94 mm 
			 | 
			|
| depth | 
			 
				73 mm 
			 | 
			|
| width | 
			 
				43.7 mm 
			 | 
			|
| product weight | 
			 
				0.19 kg 
			 | 
			
| standards | 
			 
				EN 60204-1 
			EN/IEC 60947-1 EN/IEC 60947-5-1 EN/ISO 13850 EN 1088/ISO 14119  | 
			|
|---|---|---|
| resistance to electrostatic discharge | 
			 
				6 kV on contact EN/IEC 61000-4-2 
			8 kV in air EN/IEC 61000-4-2  | 
			|
| resistance to electromagnetic fields | 
			 
				10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3 
			3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3  | 
			|
| resistance to magnetic fields | 
			 
				30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 
			 | 
			|
| resistance to fast transients | 
			 
				3 kV power lines (DC) EN/IEC 61000-4-4 DC 
			2 kV I/O lines EN/IEC 61000-4-4  | 
			|
| surge withstand | 
			 
				1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC 
			1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC  | 
			|
| resistance to conducted disturbances | 
			 
				10 V 0.15...80 MHz EN/IEC 61000-4-6 
			 | 
			|
| electromagnetic emission | 
			 
				Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC 
				61131-3 
			Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3  | 
			|
| ambient air temperature for operation | 
			 
				-10...55 °C horizontal installation 
			 | 
			|
| ambient air temperature for storage | 
			 
				-25...70 °C 
			 | 
			|
| relative humidity | 
			 
				10...95 % without condensation in operation 
			10...95 % without condensation in storage  | 
			|
| IP degree of protection | 
			 
				IP20 EN/IEC 60529 terminals 
			 | 
			|
| pollution degree | 
			 
				2 
			 | 
			|
| operating altitude | 
			 
				0...2000 m 
			 | 
			|
| storage altitude | 
			 
				0...3000 m 
			 | 
			|
| vibration resistance | 
			 
				+/- 3.5 mm 5...150 Hz IEC 60068-2-6 
			 | 
			|
| shock resistance | 
			 
				15 gn 11 ms IEC 60068-2-27 
			 | 
			|
| mechanical robustness | 
			 
				Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27 
			 | 
		