Schneider ATV930D15M3 Variable speed drive - ATV930 - 15kW - 200/240V- with braking unit - IP21
| range of product | 
				Altivar Process ATV900 | |
|---|---|---|
| product or component type | 
				Variable speed drive | |
| device application | 
				Industrial application | |
| device short name | 
				ATV930 | |
| variant | 
				Standard version With braking chopper | |
| product destination | 
				Asynchronous motors Synchronous motors | |
| mounting mode | 
				Wall mount | |
| EMC filter | 
				Without EMC filter | |
| IP degree of protection | 
				IP21 conforming to IEC 61800-5-1 | |
| degree of protection | 
				UL type 1 conforming to UL 508C | |
| type of cooling | 
				Forced convection | |
| supply frequency | 
				50...60 Hz (+/- 5 %) | |
| network number of phases | 
				3 phases | |
| [Us] rated supply voltage | 
				200...240 V (- 15...10 %) | |
| motor power kW | 
				18.5 kW (normal duty) | |
| motor power hp | 
				25 hp (normal duty) | |
| line current | 
				66.7 A at 200 V (normal duty) | |
| prospective line Isc | 
				50 kA | |
| apparent power | 
				22.7 kVA at 240 V (normal duty) | |
| continuous output current | 
				78.4 A at 4 kHz (normal duty) | |
| maximum transient current | 
				94.1 A during 60 s (normal duty) | |
| asynchronous motor control profile | 
				Optimized torque mode Constant torque standard Variable torque standard | |
| synchronous motor control profile | 
				Synchronous reluctance motor Permanent magnet motor | |
| speed drive output frequency | 
				0.1...599 Hz | |
| nominal switching frequency | 
				4 kHz | |
| switching frequency | 
				2...16 kHz adjustable | |
| safety function | 
				STO (safe torque off) SIL 3 | |
| number of preset speeds | 
				16 preset speeds | |
| communication port protocol | 
				Ethernet/IP Modbus TCP Modbus serial | |
| option module | 
				Slot A : communication module for Profibus DP V1 | 
| output voltage | 
				<= power supply voltage | |
|---|---|---|
| motor slip compensation | 
				Not available in permanent magnet motor law Adjustable Can be suppressed Automatic whatever the load | |
| acceleration and deceleration ramps | 
				Linear adjustable separately from 0.01...9999 s | |
| braking to standstill | 
				By DC injection | |
| protection type | 
				Motor : thermal protection | |
| frequency resolution | 
				Display unit : 0.1 Hz | |
| electrical connection | 
				Control, screw terminal : 0.5...1.5 mm² (AWG 20...AWG 16) | |
| connector type | 
				2 RJ45 (on the control block) for Ethernet IP/Modbus TCP | |
| physical interface | 
				2-wire RS 485 for Modbus serial | |
| transmission frame | 
				RTU for Modbus serial | |
| transmission rate | 
				10/100 Mbit/s for Ethernet IP/Modbus TCP | |
| exchange mode | 
				Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus 
				TCP | |
| data format | 
				8 bits, configurable odd, even or no parity for Modbus serial | |
| type of polarization | 
				No impedance for Modbus serial | |
| method of access | 
				Slave for Modbus TCP | |
| supply | 
				External supply for digital inputs : 24 V DC (19...30 V) current 
				<= 1.25 mA (overload and short-circuit protection) | |
| local signalling | 
				3 mono/dual colour LED for local diagnostic | |
| width | 
				226 mm | |
| height | 
				673 mm | |
| depth | 
				274 mm | |
| product weight | 
				27.3 kg | |
| analogue input number | 
				3 | |
| analogue input type | 
				Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC 
				impedance 30 kOhm, resolution 12 bits | |
| discrete input number | 
				10 | |
| discrete input type | 
				Programmable DI1...DI8 : 24 V DC (<= 30 V) impedance 3.5 kOhm | |
| input compatibility | 
				Discrete input DI1...DI8 : level 1 PLC conforming to EN/IEC 
				61131-2 | |
| analogue output number | 
				2 | |
| discrete output number | 
				2 | |
| discrete output type | 
				Logic output DQ+ : 0...1 kHz (<= 30 V) DC, 100 mA | |
| sampling duration | 
				Discrete input DI1...DI8 : 2 ms (+/- 0.5 ms) | |
| accuracy | 
				Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature 
				variation 60 °C Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °C | |
| linearity error | 
				Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value | |
| maximum switching current | 
				Relay output R1 on resistive load (cos phi = 1) : 3 A at 250 V 
				AC | |
| relay output number | 
				3 | |
| relay output type | 
				Configurable relay logic R1 : fault relay NO/NC electrical 
				durability 100000 cycles | |
| refresh time | 
				Relay output R1, R2, R3 : 5 ms (+/- 0.5 ms) | |
| minimum switching current | 
				Relay output R1, R2, R3 : 5 mA at 24 V DC | |
| isolation | 
				Between power and control terminals | |
| specific application | 
				Process | |
| IP degree of protection | 
				IP21 | |
| motor starter type | 
				Variable speed drive | 
| insulation resistance | 
				> 1 mOhm at 500 V DC for 1 minute to earth | |
|---|---|---|
| noise level | 
				71.5 dB conforming to 86/188/EEC | |
| power dissipation in W | 
				97 W (natural convection) at 200 V switching frequency 4 kHz | |
| vibration resistance | 
				1.5 mm peak to peak (f = 2...13 Hz) conforming to IEC 60068-2-6 | |
| shock resistance | 
				15 gn during 11 ms conforming to IEC 60068-2-27 | |
| volume of cooling air | 
				240 m3/h | |
| operating position | 
				Vertical +/- 10 degree | |
| THDI | 
				<= 48 % from 80...100 % of load conforming to IEC 61000-3-12 | |
| electromagnetic compatibility | 
				Electrostatic discharge immunity test level 3 conforming to IEC 
				61000-4-2 | |
| pollution degree | 
				2 EN/IEC 61800-5-1 | |
| environmental characteristic | 
				Chemical pollution resistance class 3C3 conforming to EN/IEC 
				60721-3-3 | |
| relative humidity | 
				5...95 % without condensation conforming to IEC 60068-2-3 | |
| ambient air temperature for operation | 
				50...60 °C with derating factor | |
| ambient air temperature for storage | 
				-40...70 °C | |
| operating altitude | 
				1000...4800 m with current derating 1 % per 100 m | |
| standards | 
				UL 508C | |
| product certifications | 
				UL CSA REACH TÜV | |
| marking | 
				CE | 